Document Type

Article

Publication Date

7-2022

Publisher

Wiley

Source Publication

AWWA Water Science

Source ISSN

2577-8161

Original Item ID

DOI: 10.1002/aws2.1294

Abstract

Reverse osmosis (RO) typically removes >98% arsenate (As[V]) but removes arsenite (As[III]) comparatively poorly (approximately 50%–80%). Therefore, oxidizing As(III) to As(V) can improve arsenic removal using RO. In this study, electrolytic oxidation was used to oxidize As(III) in the feed water, and an extreme low-pressure RO membrane was subsequently used to remove the arsenic. Using Ti/IrO2 electrodes under 30 mA DC current in 500 mg/L NaCl solution primarily generated free chlorine, which completely oxidized 300 μg/L As(III) to As(V). Subsequent arsenic removal by RO increased from 54.2% without oxidation to 98.2% with oxidation. Using electrolysis-RO, arsenic removal significantly increased beyond RO alone, even in the presence of ferrous iron and natural organic matter. When sulfide and As(III) are present in water, they react to produce thioarsenate ions, the formation of which increased As(III) removal to 90% without electrolytic oxidation and electrolytic oxidation did not improve arsenic removal beyond these levels.

Comments

Accepted version. AWWA Water Science, Vol. 4, No. 4 (2022). DOI. © 2022 Wiley. Used with permission.

mayer_15872acc.docx (201 kB)
ADA Accessible Version

Share

COinS